Home >> Plastic Flow Meter >> Flange type plastic flow meter
prev
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
Flange type plastic flow meter
next
sku: FM-FTFM-01

Flange type plastic flow meter

Description:
Before installation, take out foam supports in the tube carefully. Make sure the rubber ring is installed correctly on the indentation.

    Product Details

    Inquiry Now

Plastic flow meter LZB-S(long tube)

Modcl Flowrate
(water 20°C)
L
mm
D1 Condition
Socket FBSP
thread
      LZB-15S 2-20L/h
3-30 L/h
4-40 L/h
5-50 L/h
6-60 L/h
10-100 L/h
16-160 L/h
25-250 L/h
40-400 L/h
50-500 L/h
60-600 L/h
100-1000 L/h
      280       Φ20       G½“       Accuracy:
±4%   Pressure:
≤1MPa   Temp.:
0℃-60℃
LZB-25S 100-1000L/h
160-1600 L/h
250-2500 L/h
300-3000 L/h
  380   Φ32   G ¾“
LZB-40S
(with guiderod)
0.4-4m³/h
0.6-6 m³/h
1-10 m³/h
  420   Φ50   None
  LZB-50S   0.4-4 m³/h
0.6-6 m³/h
1-10 m³/h
    435     Φ63     G1½“
1.6-16 m³/h
(with guiderod)

 

Tips:

1.There are three connection types: BSP thread type, socker-end type,and flange type.(This structure sketch takes socket-end connection type as example.)

2.Flowmeter is used for measuring the flow rate of liquid or air.

 


LZB-S Plastic flow meter(short tube)

(1)Before installation, take out foam supports in the tube carefully. Make sure the rubber ring is installed correctly on the indentation.
(2)This Flowmeter can be equipped with ABS pipe or PVC pipe by using special glue to connect. It also has flange or thread connection.
(3)This flowmeter should be installed vertically and be convenient to read the scale. When reading, keep the sight and the float horizontal.(General standard: the best flow to be measured should be 50%~70% of max flowrate. Try not use the maximum value.)
(4)The straight lengths of both inlet and outlet pipes connected with the flowmeter should be more than five times of the flowmeter’s length.
(5)The pressure of liquid should be stable. If the pressure of liquid is not stable, it will lead the wave of floater and cannot measure correctly, then a buffer or setting adjuster should be set above the flowmeter.

Model Flowrate
(Water 20oC)
L mm D1 Condition
Socket FBSP
Thread
LZB-15S (with guiderod) 5-50L/h
6-60L/h
10-100L/h
16-160L/h
25-250L/h
40-400L/h
60-600L/h
100-1000L/h
    200     Φ20     G½“             Accuracy:
±4%   Pressure:
≤1MPa   Temp.:
0oC-60oC
LZB-25S (with guiderod) 100-1000L/h
160-1600L/h
250-2500L/h
300-3000L/h
  230   Φ32   G¾“
LZB-32S
(with guiderod)
400-4000L/h
600-6000L/h
288 Φ40 G1”
LZB-50S
(with guiderod)
0.4-4m³/h
0.6-6 m³/h 
1-10 m³/h
1.6-16 m³/h
  341   Φ63   G1½”
LZB-65S     
(with guiderod)
3-16m³/h  
5-25m³/h  
8-40m³/h 
10-50m³/h
12-60m³/h
  430   Φ75   G2”
LZB-80S
(with guiderod)
3-16m³/h
5-25m³/h
8-40m³/h
10-50m³/h
12-60m³/h
  533   DN80  
flange
  None
LZB-100S
(with guiderod)
8-50m³/h
10-60m³/h
14-90m³/h
18-120m³/h
18-150m³/h
20-180m³/h
20-200m³/h
20-220m³/h
    555   DN100
flange
    None
LZB-125S   
(with guiderod)
DN125   flange
LZB-150S
(with guiderod)
DN150 
flange
 
  • *Subject:
  • Your Name:
  • Your Phone Number:
  • *Your E-Mail:
  • *Content:

    Note:HTML is not translated!